Optimizing 3D-printed workpieces for radiotherapy application: modelling the CT number and print time

dc.contributor.authorKadiri, Sehad
dc.date.accessioned2025-07-17T07:34:19Z
dc.date.issued2025-07-17
dc.descriptionOptimizon printimin 3D për aplikime radioterapie duke modelluar CT.
dc.description.abstractThis study aims to analyze the influence of specific printing parameters, including infilling, print speed, and layer height, on the CT numbers and printing time of 3D-printed workpieces fabricated from Polylactic Acid (PLA). The primary objective is to optimize these parameters to attain desired CT numbers and print time for radiotherapy applications. To achieve this objective, we employed the Taguchi experimental design and regression analysis methodologies. Aseries of experiments were conducted to systematically assess the effects of varying infilling, print speed, and layer height values on the CTnumbers and printing time of the PLA workpieces. The resulting data were then used to create mathematical models for predicting optimal parameter settings. Our investigations revealed that specific adjustments to infilling and layer height significantly influence the CT numbers and printing time of 3D-printed workpieces. By leveraging the developed mathematical models, precise predictions can be made to optimize independent parameters for the desired CT numbers and printing times, enhancing the efficacy of 3D-printed workpieces for radiotherapy applications. This research contributes to the advancement of 3D-printed workpieces utilized in radiotherapy, offering a pathway to enhance the accuracy and efficiency of treatment delivery. The optimization of printing parameters outlined in this study provides a valuable tool for clinicians and researchers in the field, ultimately benefiting patients undergoing radiotherapy treatments.
dc.identifier.citationKadiri, S., Jakupi, K., Dukovski, V., & Hodolli, G. (2024). Optimizing 3D‑printed workpieces for radiotherapy application: Modelling the CT number and print time. Biomedical Physics & Engineering Express, 10(2), Article 025009. https://doi.org/10.1088/2057-1976/ad1d0b
dc.identifier.urihttps://repository.aab-edu.net/handle/123456789/519
dc.language.isoen
dc.publisherAAB College
dc.subject3D
dc.subjectPLA
dc.subjectelectron density
dc.subjectradiotherapy
dc.subjectoptimizing
dc.titleOptimizing 3D-printed workpieces for radiotherapy application: modelling the CT number and print time
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Sehad Kadiri 1.pdf
Size:
736.08 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
257 B
Format:
Item-specific license agreed to upon submission
Description:

Collections